176 research outputs found

    First results from dark matter search experiment with LiF bolometer at Kamioka Underground Laboratory

    Get PDF
    Tokyo group has performed first underground dark matter search experiment in 2001 through 2002 at Kamioka Observatory(2700m.w.e). The detector is eight LiF bolometers with total mass 168g aiming for the direct detection of WIMPs via spin-dependent interaction. With a total exposure of 4.1 kg days, we derived the limits in the a_p-a_n (WIMP-nucleon couplings) plane and excluded a large part of the parameter space allowed by the UKDMC experiment.Comment: 15 pages, 5 figure

    First Results from Dark Matter Search Experiment in the Nokogiriyama Underground Cell

    Get PDF
    An experiment to search for hypothetical particle dark matter using cryogenic thermal detector, or bolometer is ongoing. The bolometer consists of eight pieces of 21 g LiF absorbers and sensitive NTD germanium thermistors attached to them and is installed in the Nokogiriyama underground cell which is a shallow depth site (∌15\sim 15 m w.e.). We report on the results from the first running for about ten days using this arrayed bolometer system together with appropriate shieldings and muon veto counters. From the obtained energy spectra the exclusion limits for the cross section of the elastic neutralino-proton scattering are derived under commonly accepted astrophysical assumptions. The sensitivity for the light neutralino with a mass below 5 GeV is improved by this work.Comment: 8 pages, Revtex, 4 figure

    Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

    Full text link
    The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.Comment: 10 pages, 7 figures. Presented at the 13th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD13) 7-10 October 2013 Siena, Ital

    Limits on the WIMP-Nucleon Coupling Coefficients from Dark Matter Search Experiment with NaF Bolometer

    Full text link
    We have performed the underground dark matter search experiment with a sodium fl uoride (NaF) bolometer array from 2002 through 2003 at Kamioka Observatory (2700 m.w.e.). The bolometer array consists of eight NaF absorbers with a total mass of 176 g, and sensitive NTD germanium thermistors glued to each of them. This experiment aims for the direct detection of weakly interacting massive part icles (WIMPs) via spin-dependent interaction. With an exposure of 3.38 kg days, we derived the limits on the WIMP-n ucleon coupling coefficients, a_p and a_n. These limits confirmed and tightened those derived from our previous results wit h the lithium fluoride (LiF) bolometer. Our results excluded the parameter space complementary to the results obtained b y NaI detectors of UKDMC experiment.Comment: 10 pages, 4 figure

    Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout

    Full text link
    High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to 120×40×5120\times40\times5 mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of σ=42±2\sigma =42 \pm 2 ps at 1 MeV energy deposition is obtained for counter size 60×30×560\times 30 \times 5 mm^3 with three SiPMs (3×33\times3 mm^2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.Comment: 11 pages, 17 figures, accepted by IEEE Trans. Nucl. Sc

    First report of Lasiodiplodia brasiliense causing postharvest fruit rot of Custard Apple (Annona squamosa) in Brazil.

    Get PDF
    Made available in DSpace on 2018-07-12T01:03:41Z (GMT). No. of bitstreams: 1 ART18038.pdf: 298918 bytes, checksum: 119259227882f2be45395ab20d9be69b (MD5) Previous issue date: 2018-07-09bitstream/item/179595/1/ART18038.pd

    Absorption of Scintillation Light in a 100 ℓ\ell Liquid Xenonγ\gamma Ray Detector and Expected Detector Performance

    Full text link
    An 800L liquid xenon scintillation Îł\gamma ray detector is being developed for the MEG experiment which will search for ÎŒ+→e+Îł\mu^+\to\mathrm{e}^+\gamma decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm3^3 to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and α\alpha sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.Comment: 18 pages, 10 figures (eps). Submitted to Nucl. Instr. and Meth.
    • 

    corecore